14B3T Z375 Repair Tips
Search: 14B3T Z375
Results 3
Results 3
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Panasonic | 14B3T Z375. | At switch on the set pulsates 6 times before the H.T settles at 110V and the set powers on | Replace R804 0.56 ohms. It's located in the primary of the power supply and is used for current sensing. Also note this is actually a Daewoo CP375S | ||
Panasonic | 14B3T Z375 | Excessive vertical overscan caused by a poor factory set up | Enter service mode and alter V Size:- | ||
Panasonic | TX14B3T Z375 chassis | Field collapse noticed when A1s advanced | IC301 TDA8456 - also do following mod - change C309 to 22µ 100v, add 0µ01 across R310 & fit 2R2 1w in place of jumper R420 |